Safer soft start for your big amp.

Reply
 
LinkBack Thread Tools Display Modes
  #1  
Old 09-29-2010, 08:44 AM
Senior Member
iTrader: (0)
 
Join Date: Sep 2009
Posts: 2,214
Shockwave will become famous soon enough
Default Safer soft start for your big amp.


On larger plate supplies the soft start circuit used can make a big difference in the level of protection offered. While there are countless ways to design a soft start circuit, I see them all falling into two basic categories. Time based and voltage based to control the delay between soft start and full on. The vast majority are time based. Instantly powering the primary trough a wire wound resistor usually around 100 ohms. It then shorts the resistor through a second contactor after some pre-determined amount of time to apply full power.

Here is a great opportunity to add protection beyond just the rectifiers and filter caps. This is especially useful when building a new amplifier or testing a tube of unknown condition. On the typical soft start if we have a short anywhere on the HV line, it's still going to apply full power after about a second. If we trigger the contactor that shorts the soft start resistor from the voltage across the primary of the plate transformer, we added more protection.

Since the voltage across the primary is being fed through the 100 ohm resistor, it will take time for the primary to reach 220 volts as the secondary charges the filters through the rectifiers. You can use a small relay with a 220 volt coil connected the primary to fire a larger mercury contactor that shorts the soft start. By adding a resistor to the relay coil or tightening the tension on the spring of the 220 volt relay you can add more delay if needed.

Now if there is a short on the HV line on power up, the primary voltage will be forced across the 100 ohm soft start resistor. This will hold the primary voltage low, keeping the 220 volt trigger relay de-energized and prevent the full power from ever being applied into the short. Adding an appropriate slow blow fuse in series with the 100 ohm soft start resistor will remove all power and save the resistor.

With the voltage triggered soft start you can have a shorted tube installed on power up and still protect rectifiers, filter caps, current meters, glitch resistor, meter shunts, and the plate choke just to name a few. The standard soft start would fail to protect all of these components in a case like this. Something to seriously consider if your plate supply is big enough to cause this damage.


Reply With Quote
  #2  
Old 09-29-2010, 04:50 PM
Senior Member
iTrader: (1)
 
Join Date: May 2007
Posts: 485
Crusher is on a distinguished road
Default

Hey thanks shockwave, this is a really good idea.

Reply With Quote
  #3  
Old 05-19-2013, 10:08 AM
Member
iTrader: (0)
 
Join Date: Dec 2012
Posts: 50
kb1sel is on a distinguished road
Default soft start

Actually this method is commonly used in the larger ameritron amplifiers. Like the al-82/al-1200 and the al-1500. The circuit is published on w8ji's website. A 100 ohm resistor really isn't appropriate since if the b+ has to much of a load on it from the bleeder resistors it will cause to much of a voltage drop on the switched side of the primary.Which can cause the relay which is paralleled with the plate transformer primary not to engag or a delayed engagement.

For a transformer with a 240 primary a 20 ohm resistor is more appropriate. Its also wise to put a small slow blow fuse in series with the resistor a 3 amp fuse will be more then adequate. If you are loading the b+ down with bleeder resistors by themselves or with a resonant or swinging choke setup. Then a time delayed circuit is more appropriate Since a heavy load on the b+ will cause excessive voltage drop through the resistor. Which will prevent the relay with the 240 coil from engaging . Manipulating the relays spring does not work. Every open frame relay with a 240 coil I have tried closes around 140 volts. If you lighten up on the spring tension the relay will chatter before it engages and will not fully engage any quicker.

Last edited by kb1sel; 05-19-2013 at 10:33 AM.

Reply With Quote
  #4  
Old 05-19-2013, 10:38 AM
Member
iTrader: (0)
 
Join Date: Dec 2012
Posts: 50
kb1sel is on a distinguished road
Default another idea

Maybe rectifying the relays coil voltage would work if you had a heavy load on the b+ during startup. But then you have other issues to figure out.

Last edited by kb1sel; 05-19-2013 at 10:57 AM.

Reply With Quote
Reply

Bookmarks
Worldwide Radio Forum



Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Soft start for power supply Samson34 Home Brew 3 02-27-2010 05:56 PM
Some Archives of the Old Forum Sonwatcher Announcements & Open Forum 10 12-03-2009 06:50 PM
Need Help Setting Up Radio Neuro CB Band and CB Radios 24 06-10-2009 01:30 PM


All times are GMT -7. The time now is 11:42 AM.


Powered by vBulletin®
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.6.0
Worldwide Radio Forum