TRAM D201. C706


Schematic shows it's a variable capacitor near the driver tube.
Check around, T700 (C707), the driver tube (R706, R705), one end goes to ground.

Sorry I don't have any pics of the inside to point it out, I've never repaired or purchased one of these.
Stay safe Crambone, don't let it bite you.
d201_c706.png
 
Last edited:
  • Like
Reactions: Sonar
C706 is the neutralizing adjustment for the final tube.

It's purpose is to balance the negative feedback to the final tube. Makes it stable so it won't oscillate and produce RF energy far away from your channel frequency.

The procedure to set it found in the factory manual is a bit convoluted.

Just don't make the mistake we see over and over, setting it to max the wattmeter reading.

73
 
C706 is the neutralizing adjustment for the final tube.

It's purpose is to balance the negative feedback to the final tube. Makes it stable so it won't oscillate and produce RF energy far away from your channel frequency.

The procedure to set it found in the factory manual is a bit convoluted.

Just don't make the mistake we see over and over, setting it to max the wattmeter reading.

73
What are the possible repercussions of dropping in a new final (6BQ5) without neutralizing it? While trying to figure out a problem I was having with my fs2340 I replaced the two 6BQ5 modulators but thought twice about installing a new 6BQ5 final because i couldn't go through the neutralization process. The problem was eventually rectified, but I always wondered what type of damage if any could be done by replacing a tube final in any piece of equipment that requires the final be neutralized? 73
 

dxChat
Help Users
  • No one is chatting at the moment.
  • dxBot:
    Tucker442 has left the room.
  • @ BJ radionut:
    LIVE 10:00 AM EST :cool:
  • @ Charles Edwards:
    I'm looking for factory settings 1 through 59 for a AT 5555 n2 or AT500 M2 I only wrote down half the values feel like a idiot I need help will be appreciated