reading a bird 43 meter


Use the middle scale that goes to 50.Multiply the meter reading by 100 when using the 5K slug. Bird slugs come in common multiplies of 1,2.5,and 5.Just use the appropriate scale and multiply according. A 250 watt slug would use the 25 scale and multiply by 10. A 25K slug would use the same scale but multiply by 1000.You get the picture. ;)
 
Easy to see how it could be a mistake. Someone who has never used a bird before probably isn't expecting their 4 pill to only do 400 watts. So they are thinking they are on the wrong scale.

Josh
 
distortion said:
Easy to see how it could be a mistake. Someone who has never used a bird before probably isn't expecting their 4 pill to only do 400 watts. So they are thinking they are on the wrong scale.

Josh

:p
 
distortion said:
Someone who has never used a bird before probably isn't expecting their 4 pill to only do 400 watts.
:lol :lol :lol :lol :lol :lol :lol :lol :lol :lol :lol :lol :lol :lol :lol :lol :lol :lol :lol :lol :lol :lol
 
distortion said:
Easy to see how it could be a mistake. Someone who has never used a bird before probably isn't expecting their 4 pill to only do 400 watts. So they are thinking they are on the wrong scale.

Josh

your right if his 4pill is only doing 400rms he needs to get it serviced
 