Sark 100 antenna analyzer test frequency


Thanks. I have this manual, maybe my issue with it wasn't fully understood. Look at the picture attached. The sark is showing the test frequency is 40.810 mhz. Connected to a frequency counter it is actually putting out 27.206 mhz. they should match. Right?
 
  • Like
Reactions: ClaimJumper
Good question. I haven't used mine on a single frequency yet. I'm scanning different bands on the antennas I have. In fact I never actually calibrated mine. I attached a 50 ohm dummy load to see what the SARK100 said the ohms were. Then I measured the dummy load with my multimeter, and they were exactly the same. So I called it good.
 
I know my antenna system is spot on. When I check it @40.810 it’s 49 ohm but 27.205 is off the chart. I built the cal connectors and calibrated it when I first got it. But never figured out the test frequency discrepancy‍♂️
 
I know my antenna system is spot on. When I check it @40.810 it’s 49 ohm but 27.205 is off the chart. I built the cal connectors and calibrated it when I first got it. But never figured out the test frequency discrepancy‍♂️
How did you build the calibration loads? I would like to do this myself.
 
PL259 each resistor value. Solder one lead on center pin and the other to the shield housing. I may or may not have one of them in my parts bin. If I can find one I’ll post a picture.
 
PL259 each resistor value. Solder one lead on center pin and the other to the shield housing. I may or may not have one of them in my parts bin. If I can find one I’ll post a picture.
Does the wattage matter? I have some small resistors I could use, but they're only like quarter watt.
 
This is how I made my calibration rigs. You just have to get the right combination of resistors to get the correct values. Or order the exact resistors.
View attachment 76564
I've just one thing to add here if I may, don't use wire wound resistors for this. I would use high tolerance carbon comp, maybe even metal foil, and if it's just to calibrate the sark or other low power output analyzers, I think 1/4 watt is acceptable, maybe even 1/8 watt.

If using as a dummy load or to set swr indicators on radios (actually connecting it to the radios SO239), you will want the higher wattage resistors, 5 watt comes to mind for short key downs on a stock rig and a higher wattage resistor with good thermal conductance for longer keys or higher output rigs.
 
Yeah you’re right. For me it was a one time use. And the wire wound was just stuff I had hanging around the shack. But if you know how to get my frequency out put to match the displayed frequency on my sark 100 I would appreciate any suggestions. Look at the attachment at the beginning of the thread.
 