• You can now help support WorldwideDX when you shop on Amazon at no additional cost to you! Simply follow this Shop on Amazon link first and a portion of any purchase is sent to WorldwideDX to help with site costs.

Search results

  1. N

    Heathkit HO-10 Monitor Scope for HF

    Thanks Nomad, this issue had me flummoxed for a bit. This morning I got the scope working to extent it passed the manual's section of "Test & Adjustment". Everything seems to be working fine. Dr Frankenstein, thanks again for the Assembly manual.
  2. N

    Heathkit HO-10 Monitor Scope for HF

    I think I made a mistake via my misunderstanding of Metering. I may have figured it out but I’m looking for corroboration. The Heathkit build instructions have 3 measurements of Resistance that should be attained prior to applying power for the first time. My first measurement was far too low...
  3. N

    Heathkit HO-10 Monitor Scope for HF

    That Assembly Manual really helping. I'm going step by step to verify all connections. Initial attempt to perform pre-power test measurements failed 1st step: Measure resistance btwn Ground & lug/pin 1 of V6 (Rectifier tube plate, IV2). It's lower than it should be by MO's (should be approx...
  4. N

    Heathkit HO-10 Monitor Scope for HF

    AND ....... That QST article is the bomb! Circuit upgrades for a 60 year old device. This forum has unbelievable depth in it's Human resources. Thanks again. neil, n2eye
  5. N

    Heathkit HO-10 Monitor Scope for HF

    Dr. Frankenstein, That manual is exactly what I needed. A huge thank you for the Assembly document. I looked everywhere and could not find it. I've been using pics which relies on orig builder and often fails to capture what I need a day or 2 later. Trying to stay away from the two, one-piece...
  6. N

    Heathkit HO-10 Monitor Scope for HF

    Nearly a Month later, got the new parts installed into scope but have not yet applied power. I planned on replacing every resistor pair (same value) only. After I measured a few, it was obvious they all need replacing. They all show far higher resistance than their color band values (like...
  7. N

    Newark Electronics delivers on time,

    mea culpa, Got my parts today (all of them) despite the July shipping date on first invoice. I don’t understand the why and how of it all but I’m satisfied with my order. Now it’s time to refresh this old Heathkit scope
  8. N

    New Parts: What shipping time are Members experiencing?

    OK, I put in a request for clarification. I also searched generally online and saw I was not the only person w/shipping issues. Thanks for the feedback
  9. N

    New Parts: What shipping time are Members experiencing?

    Past few years, when I need several different parts, I've been ordering from Newark Electronics. My last order was a week ago, mostly caps and a few resistors, $60 total. Everything I ordered was marked "in Stock". A few days later I'm notified my order will not ship until July 15. :oops...
  10. N

    Heathkit HO-10 Monitor Scope for HF

    Got this from eBay a weeks or 2 ago. Ordered new caps and some select resistors. Input adjustable rear panel from 1/2w to 1kw (SSB I presume) just a jumper with a signal tap to scope inputs. It's old but limited features so it's not so complicated I'd avoid using it. Will it have "use...
  11. N

    What's the purpose of the extra set of plates on this Air Var Cap? Johnson 169-25

    Same Cap! "it does serve to improve feed-line balance and reduce the potential for feed-line radiation. Most coax systems are already referenced to ground via chassis ground or shield grounding at the point where the coax enters the shack. It is a design form which is only important in terms of...
  12. N

    What's the purpose of the extra set of plates on this Air Var Cap? Johnson 169-25

    It's just 2 more caps? Yet, they are inverse-synched to the primary 2 sections. My small brain couldn't grasp the use of such an piece. Was considering it to replace my Load cap and remove the extra hardware. (1 I have now is too narrow range) but could not find specs for a Johnson 169-25. Do...
  13. N

    What's the purpose of the extra set of plates on this Air Var Cap? Johnson 169-25

    I saw this on eBay Seller wrote it came from a Viking Matchbox Tuner. neil, NYC
  14. N

    Icom inflatable Tower

    saw title thought it was a joke
  15. N

    AI strikes again.

    Mystery solved over Normally Closed vs Normally Open. The Part marking convention is denoted by whether the terminals are Bent/Straight and by the color of the insulator: Bent foot w/ white insulator is Normally Open. Straight foot w/ black insulator Normally Closed. My problem was that the...
  16. N

    AI strikes again.

    I don’t have as much electronics equip & tools as most Members but, it’s a lot. So when the relatively new Garment Steamer stops working, it looks funny if I can’t fix it. I need a thermal switch & all I need do is find one. Illegible Part # no help from Pur. So I try AI for the 2nd time...
  17. N

    1950's Eimac brochure 4cx300A, nice graphics in color, sort of.

    1st opportunity to try desoldering station (Yihua 948). I had a Lasko 42" tower fan < 1 year old that stopped spinning. I used the Yihua on one of the thru-hole PCB’s that needed attention. Have not cleaned the filter spring yet but nozzle sucked-up some big molten globs and cleared the pcb...
  18. N

    Gonset GSB-201, "Frame-Up" restoration --- A SAGA

    I’m saddened to read your plan to abandon the 201. I was watching and hoping to see it work. I had one w/the same goal that got the better of me around 2010. I still have the outer case/cage-type that the chassis slides into for anyone (free) to pick-up (Bronx). My letting-go was...
  19. N

    CBer gets NAL forfeiture order of $25,000

    Such vigilance